Stairs calculator
Calculate straight-stair geometry from floor-to-floor rise, tread depth and a measured overhead obstruction.
exact 16.5 treads with 10% waste
- Actual rise per step
- 6.938 in
- Risers
- 16 risers
- Separate treads
- 15 treads
- Total run
- 153.75 in
- Full-flight diagonal
- 189.631 in
- Headroom at entered edge
- 77.404 in
Use an approved stringer size and layout. Measured headroom at one point does not establish compliance.
Job ticket
Stairs| Material | Raw amount | With waste | To buy |
|---|---|---|---|
| Tread positions | 15 treads | 16.5 treads+1.5 treads extra | 17 treads |
| Stringers | 3 stringers | 3.3 stringers+0.3 stringers extra | 4 confirm longer stockRequired per stringer: 16.55 ft |
-
Tread positions
- Raw amount
- 15 treads
- With waste
- 16.5 treads+1.5 treads extra
- To buy
- 17 treads
-
Stringers
- Raw amount
- 3 stringers
- With waste
- 3.3 stringers+0.3 stringers extra
- To buy
- 4 confirm longer stockRequired per stringer: 16.55 ft
Order options cover the same work. Choose the package or delivery option you need.
Add unit prices (optional)
How this is calculated
Divide total rise by the target riser height and round up, with a minimum straight flight of two risers. Divide by riser count for actual rise. Multiply treads by depth. The overall rise and run form the diagonal. Measure headroom vertically to the opening underside.
Worked example
111 in total rise, 7⅜ in target riser height and 10¼ in treads, with the upper floor as the landing. Obstruction underside 106 in above the lower floor at 32 in from the first riser. Three stringers, 18 ft stock, 9 in trim, 0% waste.
- Round up 111 ÷ 7.375 to 16 risers. The actual rise is 6.9375 in.
- The upper landing leaves 15 separate treads to order. The run is 15 × 10.25 in, or 153.75 in.
- The full-flight diagonal is about 189.63 in before the trim allowance.
Sources
Frequently asked questions
Why do risers and treads differ?
The upper landing can serve as the final surface, so there is one fewer separate tread.
How are the risers rounded?
Round the count up before computing the actual rise. The solver models flights of at least two risers.
Is the diagonal the cut length?
It is the overall geometry before hangers, notches, bearing and end cuts. Confirm the actual stock and layout independently.
What does the headroom check cover?
It checks one entered obstruction edge against the straight nosing line. Inspect other points and the full walking line on site.
Will this prove code compliance?
Confirm actual rise, run, headroom, width, landings, handrail and local rules with the approved plans.