Measurements

Enter 12′ 6″, 12.5 ft or 3.8 m in a length field.

Calculation scope. Tile and grid quantities for the entered layout. Verify with a licensed professional before choosing support, hanger spacing or seismic and fire-rated assemblies.

ft if no unit
ft if no unit
ft if no unit

Ceiling rooms

Room 1
ft if no unit
ft if no unit
Acoustic ceiling panels
5 cases to order

exact 70.4 panels with 10% waste

Grid estimate assumes each border stock section is cut from one compatible piece. Verify room layout and support points before ordering.

Job ticket

Suspended ceiling tile & grid
MaterialRaw amountWith wasteTo buy
Acoustic ceiling panels 64 panels70.4 panels+6.4 panels extra 5 cases
Main beams 6 pieces6.6 pieces+0.6 pieces extra 7 pieces
4 ft cross tees 28 pieces30.8 pieces+2.8 pieces extra 31 pieces
2 ft infill tees 32 pieces35.2 pieces+3.2 pieces extra 36 pieces
Wall angle stock 8 pieces8.8 pieces+0.8 pieces extra 9 pieces
Hanger sets 12 pieces13.2 pieces+1.2 pieces extra 14 pieces
  • Acoustic ceiling panels

    Raw amount
    64 panels
    With waste
    70.4 panels+6.4 panels extra
    To buy
    5 cases
  • Main beams

    Raw amount
    6 pieces
    With waste
    6.6 pieces+0.6 pieces extra
    To buy
    7 pieces
  • 4 ft cross tees

    Raw amount
    28 pieces
    With waste
    30.8 pieces+2.8 pieces extra
    To buy
    31 pieces
  • 2 ft infill tees

    Raw amount
    32 pieces
    With waste
    35.2 pieces+3.2 pieces extra
    To buy
    36 pieces
  • Wall angle stock

    Raw amount
    8 pieces
    With waste
    8.8 pieces+0.8 pieces extra
    To buy
    9 pieces
  • Hanger sets

    Raw amount
    12 pieces
    With waste
    13.2 pieces+1.2 pieces extra
    To buy
    14 pieces
Estimates only. Check with your supplier and local code.

How this is calculated

Center the grid across the room. Use 4 ft grid courses across the mains and 2 ft courses along them. Reserve a panel per grid position, then count mains along interior 4 ft boundaries, cross tees, optional 2 ft infill tees, wall angle and hangers.

Worked example

8 × 9 ft room, 2 × 2 ft panels, 16 per case, 12 ft mains and wall angle, 4 ft hanger spacing; no waste.

  1. Across the mains, the 9 ft room splits into 2½, 4 and 2½ ft bays. The bays subdivide for the square panels.
  2. Four rows of six panel positions need 24 panels.
  3. Buy two panel cases, two main beams, nine 4 ft cross tees, twelve 2 ft infill tees, four angles and four hanger sets.

Sources

Frequently asked questions

Why count a cut panel as a full panel?

The grid reserves a panel for each position. Field crews can reuse compatible offcuts separately.

Which way do main beams run?

Enter the dimension parallel to the mains as room length.

What changes for 2 × 2 ft panels?

Each full 4 ft grid bay uses 2 ft infill tees. Edge bays use one where needed to keep panel widths at 2 ft or less.

Why round trim per wall?

Each wall gets stock before offcut reuse. This keeps the takeoff conservative.

Does it size hangers or fixture supports?

Use the grid layout and project specification for hanger spacing and separate fixture support.

Planning how to pay for the job?