Builder Tango

Attic ventilation calculator

Calculate intake and exhaust net free area and buy vent stock using the ratings on the selected products.

Measurements

Enter 12′ 6″, 12.5 ft or 3.8 m in a length field.

ft if no unit

Independently vented spaces

Compartment 1
ft² if no unit
Additional intake
13 units to order

exact 514.56 in² NFA with 0% waste

Main attic · required total
1,101.12 in² NFA
Main attic · additional intake
514.56 in² intake
Main attic · additional exhaust
550.56 in² exhaust

Orders reserve whole stock separately per compartment. Installed balance and vent locations still require review.

Job ticket

Attic ventilation
MaterialRaw amountWith wasteTo buy
Additional intake 514.56 in² NFA514.56 in² NFA+0 in² NFA extra 13 units42 in² of rated net free area per unit
Additional exhaust 550.56 in² NFA550.56 in² NFA+0 in² NFA extra 8 sticks72 in² of rated net free area per stick
  • Additional intake

    Raw amount
    514.56 in² NFA
    With waste
    514.56 in² NFA+0 in² NFA extra
    To buy
    13 units42 in² of rated net free area per unit
  • Additional exhaust

    Raw amount
    550.56 in² NFA
    With waste
    550.56 in² NFA+0 in² NFA extra
    To buy
    8 sticks72 in² of rated net free area per stick
Estimates only. Check with your supplier and local code.

How this is calculated

Verify before use. Have a building-envelope or code reviewer confirm the adopted ventilation ratio, eligibility for reductions, vent locations, clear air paths and rated net free area for each attic compartment.

Convert each attic area to square inches of required ventilation using its approved ratio. Allocate the selected exhaust percentage and the remaining intake percentage. Deduct usable existing NFA separately and reserve whole vent units or sticks for each compartment.

Worked example

1,350 ft² compartment with approved 1:300 ratio and equal allocation. 48 in² existing intake, new 48 in² intake units and 4 ft exhaust sticks rated 18 in² per foot.

  1. Required total NFA is 1,350 ÷ 300 × 144 = 648 in². Allocate 324 in² on each side.
  2. Intake needs 276 in² more. Buy six 48 in² units.
  3. Exhaust needs 324 in², so buy five 72 in² sticks.

Sources

Frequently asked questions

What does NFA mean?

Net free area is the manufacturer’s rated open area after accounting for the vent’s screen, louvers and profile.

Can I choose 1:300 for every house?

Use the exception only when a reviewer confirms the adopted prerequisites and location requirements.

Why split into compartments?

Ventilation installed in one enclosed compartment cannot automatically serve another.

Can I subtract any existing opening?

Count only serviceable openings that serve that side of the system and whose NFA is known.

Does excess exhaust make up for intake?

Each side is calculated separately. Have the planned installed balance reviewed.

Planning how to pay for the job?